Square Edge Co Centric Orifice Plate

  /> </div>
<div class=

Square Edge Co-centric Orifice Plate: These are most commonly used for flow measurement. This has special feature simple structure, high accuracy and easy installation. These Orifice Plates are recommended where Reynolds number range from 10000 to 10^7.

Eccentric

  /> </div>
<div class=

Eccentric: These are used for liquid containing solid particles which are like to sediment or for vapors likely to deposit water condensate, this orifice plates are used with its eccentric bore at the bottom side so that sedimentation of such inclusions are avoided. For Gases and Vapors it may be installed with the eccentric bore at the top side to avoid stay of gas or vapor in its vicinity

Segmental

  /> </div>
<div class=

Segmental: The bore of this type of orifice plates is a semi-circle. It used where solids are entertained in liquid or gas streams

Quadrant Edge

  /> </div>
<div class=

Quadrant Edge: The inlet edge of the bore of this orifice plate is rounded to a quarter circle. This orifice plate is principally used for measuring flow rates of low Reynolds number (Between 2000 to 10000)

Restriction Orifice Plate

  /> </div>
<div class=

Restriction Orifice Plate: These Orifice Plates are used for reducing fluid pressure. These orifice plates are slightly different from standard orifice plates.

Orifice Assembly

  /> </div>
<div class=

Integral Orifice Assembly : This type of assembly is used where the Differential Pressure Transmitter has to be mounted directly on the Orifice Assembly. This eliminates the impulse tubing from Orifice Assembly to DP Transmitter. This type of assembly is used for line size below 2” (50 NB). The transmitter in mounted on the orifice assembly with the help of 3-Way Manifold. The assembly consists of orifice plate with two integral blocks having corner taps. It also consists of a meter run pipe having length of 750mm on the upstream side and 250mm on downstream side.

Our Vision

* To embrace new technologies and methods. * To give unsurpassed products and services to the clients. * To constantly look for improvement and changes.

Site Designed & Maintained by Aman Infotech
A. P. F. C (Automatic Power Factor Control) Panels, Acrylic Rotameter, Averaging Pitot Tube Annubar, Basket Type Strainer Duplex Strainer, Basket Type Strainer Simplex Strainer, Bucket Type Strainers, By Pass Rota Meters, By Pass Rotameter, By Pass Type Rotameter, Carrier Ring, Condensing Pot, Double Window Sight Flow Indicators, Eccentric, Elecrtomagnetic Flow Meter, Electromagnetic Flow Meter, Five Way Manifolds, Flange Tape Type Rota Meters, Float And Board Level Indicators, Flow Indicator And Totaliser, Flow Measuring Instruments, Flow Nozzle, Full Bore Electromagnetic Flow Meter, Full Bore Electromagnetic Flow Meter Sanitary Grade, Full Bore Electromagnetic Flow Meter Wafer Type, Full View Sight Flow Indicators, G. T. R With Flow Switch, Glass Tube Rota Meters, Glass Tube Rotameter, Glass Tube Rotameter With Transmitter, Glass Tube Type Purge Rotameter, Glass Tube Type Rotameter, Home, Integral Orifice Assembly, Isolation Valves, Level Measurement, Loop Power Indicator, Low Flow Rotameter, Low Flow Rotameter With Dp Regulator, Magnetic Implex (Duplex Strainer), Magnetic Level Indicator, Metal Tube Rota Meters, Metal Tube Rotameter, Metal Tube Rotameter With Switching Alarm, Metal Tube Rotameter With Transmiter, Metal Tube Rotameter With Trasnmitter, Multi Stage Restriction Orifice Plate, Orifice Assembly, Orifice Flange Assembly, Orifice Plate, Paddle Type Switch, Plunger Type Switch, Positive Displacement Flow Meter, Pressure Measurement, Process Indicator And And Totaliser, Purge Rotameter With Dp Regulator, Quadrant Edge, Reflex Level Indicators, Restriction Orifice Plate, Rota Meters, Rotameter With High Flow (Latching) Switch, Rotameter With Low Flow (Latching) Switch, Segmental, Single Limb Manometer, Square Edge Co Centric Orifice Plate, Strainers, Synchronizing Panel, Three Way Manifolds, Top Mounted Level Indicator, Transparent Level Indicator, Tubular Level Indicator, Turbine Flow Meter, Two Way Manifolds, U Tube Manometer, Ultrasonic Flow Meter, V Cone, Ventury Tube, Vortex Flow Meter